Tables 1 and 2 in this chapter are derived from the trada technology ltd.
Flat roof timber span tables c24.
Supported wall a walltowhich lateralsupportisaffordedby a.
Should refer to trada document span tables for solid timber members in floors ceilings and roofs excluding trussed rafter roofs for dwellings or ask your lbc surveyor for advice.
Flat roof with no permanent access and altitude not exceeding 100m 0 75 kn m udl 0 9 kn point load most areas exceeding 100m but not exceeding 200m excluding parts of scotland pennines north east england refer to bs 6399 3 1 kn m udl 0 9 kn point load.
Span tables for flat roof joists to bs 5268 7 2 imposed loads of 0 75 kn m for maintenance and snow load are applicable where there is no permanent access no fixed ladder or staircase and most areas where the altitude does not exceed 100 metres refer to bs 6399 3.
These span tables apply only to flat roof and roof with a slope of up to 10 degrees.
Maximum clear span of flat roof joists in metres for sc3 timber spacing between joists size of roof joist 400mm 450mm 600mm 47 x 97 1 84 1 81 1 74.
Surveyors and structural engineers utilise data from tables below to help calculate the correct size strength and centres of roof timbers for the required spans and loadings.
Span tables span tables can be used to determine the size of a timber member of a particular.
C16 span table only stocked at our mitcham depot.
For timber floors between homes.
Span tables flat roof joists span tables for flat roof joists to bs 5268 7 2 imposed loads of 0 75 kn m for maintenance and snow load are applicable where there is no permanent access no fixed ladder or staircase and most areas where the altitude does not exceed 100 metres refer to bs 6399 3.
Clear span c16 joist m clear span c24 joist m 47 x 95 47 x 120 47 x 145 47 x 170 47 x 195 47 x 220 1 77 2 40 2 89 3 38 3 87 4 36 2 04 2 75 3 47 4 20 4 93 5 66 floor joists flat roof joists assumptions at 400mm centers supporting permanent load.
The section sizes are based on regularised als or cls timber.
Notches are not to exceed 0 125 of the depth of the joist and are to be located between 0 07 and 0 25 of the span from the support.
Click here to download c16 span table leaflet c24 span table our premium grade of carcassing is c24 graded.
Eurocode 5 span tables for solid timber members in floors ceilings and roofs for dwellings 3rd edition.
Stocked at all branches click here to download c24 strength class pdf document.
N ote the spansgiven in pa rt4b ofsection4 forfloorjoists rafters purlins ceilingjoists bindersand roofjoistsareclearspans i e spansbetween the facesofthesupports.
Span tables for solid timber joists.
Surveyors span tables for designing roof rafters.