If connected to a circuit network an accumulator will output its level of charge as an integer from 0 to 100 to a specified signal.
Factorio solar panel accumulator layout.
Solar panels are an unlimited source of free energy that produce no pollution.
Generated power will increase decrease linearly during dusk and dawn and no power is produced at night.
Solar panels and accumulators optimal ratio.
During daylight hours every panel provides the maximum power level 60kw.
There are either 5 36 extra accumulators or 6 38 missing solar panels.
This tutorial covers solar panel arrangements to use at various stages of the game including the building of the massive ratio perfect array from this foru.
You need 17 solar panels for each steam engine running at max capacity.
Its maximum charge discharge rate is 300 kw.
The accumulator stores a limited amount of energy when available production exceeds demand and releases it in the opposite case.
The ratios posted result in more solar panels then are needed to power factory and charge accumulators i had posted this in a topic on the steam forum a week ago when somebody was asking about solar panels and another person brought up the 0 8 1 ratio.
2224 96 5 solar panels.
Or more precisely you need power consumption in w 30 kw solar panels.
This is a 25 21 0 84 ratio solar panel accumulator layout that i came up with and i didn t see it posted anywhere so i wanted to share it with the community.
For each 5 solar panels you need 3 accumulators.
Press j to jump to the feed.
0 84 is the standard if you are building exactly the amount of power you need a little bit less than 0 84 means you have more solar panels which is good if you are planning to build too many of both and a little bit more than 0 84 means that you have more accumulators which is.
The accumulator can store up to 5 mj of energy.
The ideal ratio is 0 84 accumulators panel.
The first calculation is your accu solar ratio.
This means one solar panel produces an average of 42 kw over one day and night cycle.
It as a space efficiency of 96 5 3 5 of the tiles used by the roboport and the substations are not used by solar panel and or accumulators and an accumulator solar panel ratio of 0 84.
1 logistic network tilable.
The optimal ratio is 0 84 21 25 accumulators per solar panel and 23 8 solar panels per megawatt required by your factory this ratio accounts for solar panels needed to charge the accumulators this means that you need 1 428 mw of production of solar panels and 100mj of storage to provide 1 mw of power over one day night cycle.
Subreddit for the game factorio made by wube software.
Keep in mind that these numbers are approximate you may want to have a buffer for laser turrets if nothing else.
Press question mark to learn the rest of the keyboard shortcuts.
Overall this design has a continuous power rating excluding roboport drain of 8 232mw.
This layout has 170 accumulators and 196 panels.
Something to consider is that many people like replacing a solar panel with a radar in.